Loading ...
Loading ...
Loading ...
BGA1601-40K
VENTILATION
WARNING: 

2
(1400 cm
2



OPERATION
TO START HEATER
1. Read and carefully follow all installation, ventilation
and safety information.
2. Place heater on a stable and level surface. Make
sure the front or rear of heater are not exposed to
strong drafts.
3. Plug the power cord of heater into a three-prong,
grounded extension cord. Extension cord must be
at least 6 ft. (2 m) long and must be UL listed.

Up to 50 ft (15 m) long, use 18 AWG rated cord.
51 to 100 ft (16 to 30 m) long, use 16 AWG
rated cord.
101 to 200 ft (30.78 to 60.96 m) long, use 14 AWG
rated cord.
4. Plug extension cord into a 120 volt/60 hertz, 3-hole,
grounded outlet. The motor will start. The fan will
turn, forcing air out the front of the heater.
5. Open propane supply valve on propane tank(s)
slowly.  If not opened slowly, the excess-ow
check valve on propane tank will stop gas ow.
You may hear a click from the excess-ow check
valve closing. If this happens, reset the excess-ow
check valve by closing the propane supply valve
and opening it again slowly.
WARNING:
Be sure the motor
    

      

WARNING:
Review and understand the warnings in the Safety

6. Push in and hold the automatic control valve button
(see Figure 5). Push Piezo igniter button (see Figure
5). Keep pushing the igniter button until burner
lights. When burner lights, keep the automatic
control valve button pushed in. Release button after
30 seconds. This activates the automatic control
system.
Piezo
Igniter
Automatic Control
Valve Button
Figure 5 - Automatic Control Valve
Button and Piezo Ignitor
WARNING: If the heater is
     
while the heater is running, the thermal
      
seconds occur before the thermal limit



Page 6 / 1112/2020