4. INTRODUCTION
4.1 SCOPE
This Socket Tester can be used to determine whether socket wiring is correct or incorrect.
In conjunction with the coding table provided, the three combined indicators indicate the true
status of the wiring condition. The voltage tester detects AC voltage in outlets, lighting fixtures,
circuit breakers, wires and cables.
4.2 SPECIFICATION
Socket Tester:
Rated voltage .............................................................................................................................230V
Rated frequency................................................................................................................... 50-60Hz
Working Temperature ..................................................................0°C ~ 40°C relative humidity <80%
Size .......................................................................................................................... 71 x 62 x 62mm
Weight .......................................................................................................................................... 63g
Voltage Tester:
Voltage range ..............................................................................................................200-6000V AC
Frequency .......................................................................................................................... 50-500Hz
Measurement category...................................................................................................CAT III 600V
Power .................................................................................................................................... 2 x AAA
Weight .......................................................................................................................................... 46g
4.3 HANDLING AND STORAGE
Although these testers is small in size, care must still be taken when handling. Dropping these
testers will have an effect on the accuracy and may also result in personal injury. These testers is
not a toy and must be respected.
The environment will have a negative result on its operation if you are not careful. If the air is
damp, components will rust. If the machine is unprotected from dust and debris; components will
become clogged: And if not cleaned and maintained correctly or regularly the tester will not
perform at its best.
3. GUARANTEE
3.1 GUARANTEE
Draper tools have been carefully tested and inspected before shipment and are guaranteed to be
free from defective materials and workmanship.
Should the tool develop a fault, please return the complete tool to your nearest distributor or
contact:
Draper Tools Limited, Chandler's Ford, Eastleigh, Hampshire, SO53 1YF. England.
Telephone Sales Desk: (023) 8049 4333 or:
Product Helpline (023) 8049 4344.
A proof of purchase must be provided.
If upon inspection it is found that the fault occurring is due to defective materials or workmanship,
repairs will be carried out free of charge. This guarantee period covering parts/labour is 12 months
from the date of purchase except where tools are hired out when the guarantee period is 90 days
from the date of purchase. The guarantee is extended to 24 months for parts only. This guarantee
does not apply to normal wear and tear, nor does it cover any damage caused by misuse, careless
or unsafe handling, alterations, accidents, or repairs attempted or made by any personnel other
than the authorised Draper warranty repair agent.
Note: If the tool is found not to be within the terms of warranty, repairs and carriage charges will be
quoted and made accordingly.
This guarantee applies in lieu of any other guarantee expressed or implied and variations of its
terms are not authorised.
Your Draper guarantee is not effective unless you can produce upon request a dated receipt or
invoice to verify your proof of purchase within the guarantee period.
Please note that this guarantee is an additional benefit and does not affect your statutory rights.
Draper Tools Limited.
5. HEALTH AND SAFETY INFORMATION
5.1 GENERAL SAFETY INSTRUCTIONS FOR SOCKET TESTER USE
Warning: Do not use tester if wet or damaged in any way.
WARNING
1. In order to avoid electrical shock, use proper safety measures when working with voltages
above 32V AC rms, 42V AC peak or 60V DC.
These voltages can pose a shock hazard.
2. If a plug adapter has to be used to test a socket or a lead connection, ensure that this adapter
is in a perfect condition and that the protective conductor connection of the adapter is
continuously connected. Using the tester without continuous protective conductor leads to
faulty test results.
3. Before use, check that the instrument is in perfect working order, for example, verify the
instrument's operation with a known voltage source.
4. For socket wiring test, a clear and safe statement concerning the test result can only be given
in connection with the touching of the contact electrode.
5. This instrument cannot detect N/Earth reverse.
6. The indicators may at times light up weakly depending on the distributed capacitance of the
electrical installation.
7. Always keep the instrument dry.
8. Don't touch any conductor with hand or skin to avoid electric shock.
9. The instrument must only be used under the conditions and for the purposes for which it has
been designed.
5.2 GENERAL SAFETY INSTRUCTIONS FOR VOLTAGE TESTER USE
Warning: Do not use tester if wet or damaged in any way.
WARNING
1. In order to avoid electrical shock, use proper safety measures when working with voltages
above 32V AC rms, 42V AC peak or 60V DC.
These voltages can pose a shock hazard.
2. If a plug adapter has to be used to test a socket or a lead connection, ensure that this adapter
is in a perfect condition and that the protective conductor connection of the adapter is
continuously connected. Using the tester without continuous protective conductor leads to
faulty test results.
3. Always check the tester on a known live circuit before use.
4. Place tip of the tester near an AC voltage. If the tester detects voltage, the LED in the tip of the
tester illuminates red.
5. Always keep the instrument dry.
6. Don't touch any conductor with hand or skin to avoid electric shock.
7. The instrument must only be used under the conditions and for the purposes for which it has
been designed.
8. EXPLANATION OF SYMBOLS
8.1 EXPLANATION OF SYMBOLS
6. TECHNICAL DESCRIPTION
6.1 IDENTIFICATION
9. DISPOSAL
9.1 DISPOSAL
At the end of the machine’s working life, or when it can no longer be repaired, ensure that it is
disposed of according to national regulations.
Contact your local authority for details of collection schemes in your area.
In all circumstances:
Do not dispose of power tools with domestic waste.
Do not incinerate.
Do not abandon in the environment.
Do not dispose of WEEE* as unsorted municipal waste.
* Waste Electrical
& Electronic Equipment.
7. PREPARING THE SOCKET TESTER
- 4 - - 5 -







 Lamp 1
 Lamp 2
 Lamp 3
 Code table
 LED illuminating tip
 Battery compartment
 Pocket clip
Instruction for the Coding Table:
Left column represents the on/off state of the Lamp 1.
Middle column represents the on/off state of the Lamp 2.
Right column represents the on/off state of the Lamp 3.
230V / 50HZ
Stock No.82384
DTL SO53 1YF. UK.
Rated voltage....................... 230V/50Hz
Correct
L / N Reverse
L / E Reverse
Neutral Fault
No Earth
Live Fault
1. Plug the instrument into the socket to be tested, the state of the socket wiring is indicated by
the three combined lamps.
2. Explanations regarding the test result are described the following table, which is the same as
(but more detailed than) the Coding Table on the instrument.
Lamp 1 Lamp 2 Lamp 3 Test Result
The socket wiring is correct
Live wire and neutral wire are reversed
Live wire and earth wire are reversed
There is no neutral wire
There is no earth wire
There is no live wire
Note:
means “LAMP ON”
means “LAMP OFF”
Warning!
WEEE
Do not dispose of Waste Electrical & Electronic Equipment in with
domestic rubbish
Loading ...