PERFORMANCE DATA SHEET
Water Filtration System
Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specied in NSF/ANSI Standards 42 and 53.
Substance
Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Inuent
Inuent Challenge
Concentration
Maximum
Efuent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class I*
50% reduction
85% reduction
2.0 mg/L
7,300,000 #/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.20 mg/L
75,000 #/mL**
97
99
97.2
99.4
Contaminant
Reduction
NSF Reduction
Requirements
Average
Inuent
Inuent Challenge
Concentration
Maximum
Efuent
Minimum %
Reduction
Average %
Reduction
Live Cysts
99.95% 160,000/L 50,000/L min. 54/L
99.97 99.99
Asbestos 99% 87 MFL 10
7
to 10
8
bers/L
††
0.17 MFL 99 99
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010 mg/L 0.010
mg/L
0.160 mg/L 0.140
mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.005 mg/L
99.4
98.6
99.4
98.6
Lindane 0.0002 mg/L 0.0019 mg/L 0.002 mg/L ± 10% 0.00002 mg/L 98.9 99
Toxaphene 0.003 mg/L 0.014 mg/L 0.015 mg/L ± 10% 0.001 mg/L 93 93
Atrazine 0.003 mg/L 0.0094 mg/L 0.009 mg/L ± 10% 0.0005 mg/L 94.5 94.7
2,4 - D 0.07 mg/L 0.220 mg/L 0.210 mg/L ± 10% 0.028 mg/L 87.5 96.1
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is important that operational, maintenance, and lter
replacement requirements be carried out for the product
to perform as advertised. Property damage can occur if all
instructions are not followed.
Use replacement lter according you ltration system, see“Ice
and Water” in the User Guide.
Water Filter:
Water Filtration System Style 1 - Order Part # EDR1RXD1
Water Filtration System Style 2 - Order Part # EDR2RXD1
When the water lter status changes from TURN OFF to
RED light on your control panel, it is recommended that you
replace the lter.
After changing the water lter, ush the water system. See
“Water and Ice Dispensers” or “Water Dispenser” in the User
Instructions or User Guide.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state
and local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certied for cyst reduction may be used
on disinfected waters that may contain lterable cysts.
Refer to the “Warranty” section (in the User Instructions
or User Guide) for the Manufacturer’s name, address and
telephone number.
Refer to the “Warranty” section (in the User Instructions or
User Guide) for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
System tested and certied by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Based on the use of Cryptosporidium parvum oocysts
††
Fibers greater than 10 um in length
NSF is a registered trademark of NSF International.