1.0 INTRODUCTION
1.1 SPECIFICATIONS
TABLE 1
ITEM
NATURAL GAS (NG)
PROPANE (LP)
INPUT: Hi
26,000 Btu/hr (7.62 kW)
26,000 Btu/hr (7.62 kW)
INPUT: Lo
18,000 Btu/hr (5.28 kW)
18,000 Btu/hr (5.28 kW)
MANIFOLD PRESSURE: Hi
COLLECTEUR DE PRESSION: FORT
3.5” w.c. (0.87 kPa) 10.0” w.c. (2.49 kPa)
MANIFOLD PRESSURE: Lo
COLLECTEUR DE PRESSION:
FAIBLE
1.7” w.c. (0.42 kPa) 6.4” w.c. (1.59 kPa)
GAS INLET SUPPLY PRESSURE:
ENTREE DE PRESSION
Minimum: 5.0” w.c. (1.2 kPa)
Minimum: 7.0” w.c. (1.74 kPa)
Maximum: 13.5” w.c. (3.4 kPa)
Maximum: 13.5” w.c. (3.4 kPa)
ORIFICE SIZE: @ 0-4500
FORMAT D'ORIFICE:
# 41 DMS # 54 DMS
AIR SHUTTER
VOLET DE L’AIR
OPEN 1/8”min
(3.175mm)
OPEN 1/2min
(12.7mm)
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
Skytech AF-40004
Robertshaw
Apex Control B081
Skytech AF-40004
Robertshaw
Apex Control B081
VENTING
ÉVACUATION
2-ply aluminum vent, ICC venting,
Duravent , Security Venting, Selkirk or
Metal-Fab Venting
2-ply aluminum vent, ICC venting
Duravent, Security Venting, Selkirk or
Metal-Fab Venting
FAN
VENTILATEUR
Variable Speed (115 Volt) Variable Speed (115 Volt)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
PLATE.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
PLAQUE SIGNALÉTIQUE.
Loading ...
Loading ...
Loading ...