Instructions for Use - Page 7

For BQ1096NG. Also, The document are for others Gasmate models: BQ1096

Loading ...
Loading ...
Loading ...
6
WARNING
• Improper installation, adjustment, alteration, service or maintenance can cause injury
or property damage.
• Read the instructions thoroughly before installing or servicing this equipment.
• THIS APPLIANCE MUST NOT BE INSTALLED OR USED INDOORS.
• NATURAL GAS APPLIANCE. TO BE INSTALLED ONLY BY AN AUTHORISED PERSON.
• THE AUTHORISED PERSON WILL PROVIDE A CERTIFICATE OF COMPLIANCE.
• A Gasmate NGC30 or NGC40 AGA approved natural gas pressure regulator must be installed in the pipeline and
be set at 1 kPa.
NATURAL GAS CONVERSION
TO BE INSTALLED ONLY ON OR IN A NON-
COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained.
Tools Required:
Screw driver, adjustable spanner, Phillips head screw
driver.
GAS PIPING
1. This appliance is only to be installed by an authorised
person.
2. Check with local and state plumbing and heating
codes regarding sizing of the gas lines.
3. All gas pipe connections must be sealed with a gas
pipe compound resistant to Natural Gas.
4. Installation of a drip leg if required in the gas supply
line must conform to AS5601.
5. When checking for gas leaks, do not use an open
flame. Use a soap and water solution and check for
bubbles indicating gas leakage.
6. Installation of 1/8” NPT plugged tapping, accessible
for test gauge connections, is required upstream of
the gas supply connection.
Warning
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Read
the instructions thoroughly before installing or servicing
this equipment.
SERVICING INSTRUCTIONS
Appliances should be serviced at least annually and
servicing must only be carried out by a Licensed Plumber
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then replace
the Burner ensuring it is firmly secured.
Minimum Clearance for Ventilation:
Rear - 50mm Side - 50mm
NOTE TO THE INSTALLER:
The injector size is increased by removing the Propane
Nozzle (outer brass cap) and leaving the Natural Gas
Nozzle in place. Ensure the Natural gas nozzle is still
tight and in the correct position and the hole size is
correct.
To adjust the turndown/low remove the control knobs
to allow access to the “LOW” adjustment screw. With a
small blade screwdriver turn the brass screw fully anti-
clockwise.
TEST OPERATION OF APPLIANCE
BEFORE LEAVING.
Conversion ONLY to be done by an authorised person.
Overall Dimensions
Length Width Height
BQ1096 933mm 609mm 253mm
Loading ...