13
F0
Defrost Type
00=defrost by
turning of comp.
00
C11
Comp.
Force
Running
Time
00=comp. Stop /
01-99min=starting
time
0 min
F1
Max defrost
duration
01~60 min.
20 min.
C12
Alarm
Output Type
00=contact
actuation when
alarm / 01=contact
disconnect when
alarm
01
F2
Defrost
Interval
XXhr/time
00~24 hr.
00
C13
Normal
State temp.
display type
00=liquid bottle
temp / 01=cabinet
air temp.
00
F4
Temp.
displaying on
screen when
defrost
00= normal Temp;
01=latest Temp.
02=Fixed Temp. ;
03=showing “dEF”
on screen
00
CF
Temperature
Unit
°C=Celsius /
°F=Fahrenheit
°C
C1
High Temp
Air Alarm
C2~20.0°C / 68.0°F
9.0°°C / 48.2°F
do1
00=do not alarm /
01=99
min=delayed alarm
02 min
C2
Low Temp Air
Alarm
-19.9°C / 3.8°F~C1
1.0°°C / 33.8°F
do2
Comp.
status when
door open
0=stop /
01=original status
0 1
do3
Light status
when door
open
00=start /
01=original status
0 1