14
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
Compressor
Running
Activation of 2nd
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan
Running
LAE Control Icons
LAE Electronic Control
HOW TO INITIATE A MANUAL DEFROST
May need to unlock control.
WHY:
A ONE TIME ADDITIONAL DEFROST MAY BE NECESSARY
TO CLEAR ACCUMULATED FROST/ICE FROM EVAPORATOR
COIL.
HOW:
The method to initiate a manual defrost is determined by
the Defrost Mode Parameter “DTM” preprogrammed in
the controller.
A. REGULAR TIME DEFROST (TIM)
If controller is preprogrammed for TIM”, press and
release the Manual Defrost button until dEF” appears.
B. REAL TIME CLOCK (RTC)
If controller is preprogrammed for “RTC” press the and
hold the Manual Defrost button for 5 seconds until
dh1” appears. Release the Manual Defrost button
and then press and hold for an additional 5 seconds
until dEF” appears.
DEFROST WILL ONLY TERMINATE ONCE A SPECIFIC PRESET
TEMPERATURE OR A PRESET TIME DURATION IS REACHED.