Electrical Requirements Gas Supply Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
120-Vofi, 60-Hz., AC-only, 15- or 20-amp
fused electdcal supply is required.
(Time-delay fuse or circuit breaker is
recommended.) It is recommended that
a separate circuit serving only this dryer
be provided.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the
event of malfunction or breakdown,
grounding will reduce the risk of electric
shock by providing a path of least
resistance for electric current. This dryer
is equipped with a cord having an
equipment*grounding conductor and a
grounding plug. The plug must be
plugged into an appropriate outlet that is
properly installed and grounded in
accordance with all local codes and
ordinances.
WARNING: Improper connection
of the equipment grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
service representative or personnel if
,ou are in doubt as to whether the dryer
is properly grounded. Do not modify the
plug provided with the dryer: if it will not
fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVETHESEINSTRUCTIONS
Explosion Hazard
Use a new AGA or CSA approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas
connections.
If connected to LP, have a qualified
person make sure gas pressure
does not exceed 13" (33 cm) water
column.
Examples of a qualified person
include:
licensed heating personnel,
authorized gas company personnel,
and authorized service personnel.
Failure to do so can result in death,
explosion, or fire.
Gas Type
Natural Gas:
This dryer is equipped for use with
NATURAL GAS. It is design-certified by
CSA International for L.P. (propane or
butane) gases with appropriate
conversion.
Your dryer must have the correct
burner for the type of gas in your
home. Burner information is located
on the rating plate in the door well of
your dryer. If this information does not
agree with the type of gas available,
contact your local Sears store or
Sears Service Center.
L.P. gas conversion:
Conversion must be made by a
qualified technician.
No attempt shall be made to convert the
appliance from the gas specified on the
model/serial rating plate for use with a
different gas without consulting the
serving gas supplier.
9