INSTALLATION
The machine has to be laid in vertical position, on a level surface with sturdiness suitable for the
load. DO NOT OPERATE MACHINE WITHOUT LEVELING FEET IN PLACE! Leveling feet need to
be adjusted down, such that the front casters are raised off the surface of the floor and the unit is
level.
Electric Connection
The electric connection is to be carried out by a skilled electrician, in compliance
with the procedures, state/local codes and the regulation in force in the country of
installation. Make sure that the voltage and the frequency of the equipment are the
same of the identification plate of the machine. Damage to the machine resulting
from incorrect electrical connection will void all warranties.
DO NOT REMOVE OR TAMPER THE PROTECTIONS
AND THE ELECTRICAL AND MECHANICAL SAFETY
DEVICES THAT THE MACHINE IS PROVIDED WITH.
CONTROL PANEL
The control panel is used for the operation of the spiral mixer by the user. In order to operate the control
panel, the Mains Power Switch (left side of the machine) must be switched on.
Start Button - Begins the mixing operation. Timer(s) must be set or the unit must be in emergency bypass
to start.
Stop Button - Stops the mixing operation independent of the timer(s), Emergency Stop and safety
switches. Typically used when the timer(s) are being bypassed and the unit needs to stop
and restart for the remainder of a timed mix or when the unit is to be shut off when the
emergency bypass time has expired.
START BUTTON
TIMER FIRST
SPEED
TIMER SECOND
SPEED
POWER
LIGHT
EMERGENCY STOP
EMERGENCY TIMER
SELECTOR BYPASS
(
TIMER EXCLUSION
)
REVERSE
BOWL
LIGHTS FOR GROUND
ALARM OR THERMAL
ALARM
SELECT BUTTON TO SET
THE TIMES FOR FIRST
AND SECOND SPEED
BUTTONS TO SET THE
WORKING TIME
STOP BUTTON
Loading ...