Sencor SFT 3113BK Tower Fan

User Manual - Page 4

For SFT 3113BK.

PDF File Manual, 4 pages, Read Online | Download pdf file

SFT 3113BK photo
Loading ...
Loading ...
Loading ...
- 4 - Copyright © 2021, Fast ČR, a.s.
04/2021
EN
Tower Fan
User'smanual
Prior to using this appliance, please read the user‘smanual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of
appliances. Only use the appliance in the manner described in this user‘smanual.
Keep this user‘smanual in asafe place where it can be easily retrieved for future use.
We recommend saving the original cardboard box, packaging material, purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event
of transportation, we recommend that you pack the appliance in the original box
from the manufacturer.
DESCRIPTION OF THE FAN
A1 Rotating speed control
A2 Air outlets
A3 Base
A4 Air inlets
DESCRIPTION OF THE CONTROL PANEL
B1 Button - serves to set the fan
speed
B2 Button
- serves to set the timer
B3 Button
- serves to turn the
appliance on / off
B4 Button
- serves to turn
horizontal oscillation on / off
B5 Button
- serves to select the
operating mode
DESCRIPTION OF THE REMOTE CONTROL
C1 Button - serves to turn
horizontal oscillation on / off
C2 Button
- serves to set the timer
C3 Button
- serves to turn the
appliance on / off
C4 Button
- serves to select the
operating mode
C5 Button
- serves to set the fan
speed
INSTALLING THE BASE
The fan is supplied from the factory with adisassembled base.
1. Take the body of the fan out of the packaging material and carefully turn it
upside down – see figure D1.
2. Place both parts of the base A3 against the bottom part of the body of the fan.
Check that the power cord passes through the hole in the middle of the base
A3 – see figure D2.
3. Carefully push both parts of the base A3 until they click into the body of the fan
– see figure D3.
4. Using the supplied bolts, secure the base A3 in place – see figure D4.
USING THE FAN
Place the fan on ahorizontal, stable, dry and smooth surface within reach of apower
socket. Connect the power cord to apower socket.
Turning on / off
Press button B3, to turn on the fan. The power indicator light will be lit. Press button
B3 again to turn off the fan.
Speed setting
To set the speed of the fan, use button B1. Repeatedly press button B1 to toggle
through the speeds in the following order: L(low speed) – M(medium speed) – H(high
speed). Each time the button is pressed, the indicator of the respective speed will also
be lit on the control panel.
Setting the timer
To set the timer, use button B2. The timer can be set in the range of 30 minutes
to 7 hours and 30 minutes. Each time button
B2 is pressed, the timer duration
is increased as follows: 30minutes – 1hour – 2hours – 4hours. Indicator lights will
gradually be lit on the control panel A1, indicating the total duration of the timer.
After the set time has elapsed, the fan will turn off automatically.
Setting horizontal oscillation
Pressing button B4 will start the left to right oscillation of the fan. Pressing button
B4 again will turn off the oscillation. The fan will remain turned at the angle at
which it was stopped.
Selecting an operating mode
To select an operating mode, use button B5. Repeatedly press button B5 to
select the required operating mode: NORMAL (standard mode) – NATURE (natural air
flow mode) – SLEEP (sleep mode). If the operating mode NATURE or SLEEP is selected,
the respective indicator will also be lit on the control panel A1.
The default mode is NORMAL (normal mode).
Controlling the fan using the remote control
Controlling the fan using the remote control is the same as using the control panel A1.
The symbols on the remote control correspond to the symbols on the control panel
A1.
CLEANING AND MAINTENANCE
Before cleaning it, make sure that the fan is turned off and disconnected from the
power socket. Clean the fan regularly to ensure its long lifetime.
For cleaning, do not use cleaning products with an abrasive effect, solvents, etc. that
could damage the appliance.
Warning:
To prevent the risk of injury by electrical shock, do not submerge
the appliance, power cord or power plug in water or any another
liquid.
To clean the outer surface of the of the fan, use aclean, lightly dampened cloth. Then
wipe everything so that it is thoroughly dry. Ensure that moisture does not enter
through the air inlets or outlets into the fan.
You can also remove any dirt inside the air inlet or outlet by using avacuum cleaner
with abristle brush.
Note:
Regularly check that the bolts on the base A3 are securely tightened.
STORAGE
If you will not be using the fan for alonger period of time, store it in aclean, dry
location that is out of reach of children.
TECHNICAL SPECIFICATIONS
Rated voltage range .........................................................................................................220–240V~
Rated frequency..............................................................................................................................50Hz
Rated power input .......................................................................................................................... 50W
Noise level ....................................................................................................................................56 dB(A)
Maximum air flow of the fan ......................................................................................... 7.38m
3
/min
Operation value ...........................................................................................................0.2 (m
3
/min)/W
Maximum air flow speed ....................................................................................................... 0.68m/s
Standard for measuring the operating value ............................................... EN ISO 5801:2008
Contact for further information ..FAST ČR, a.s., USanitasu 1621, 251 01 Říčany, Czechia
The declared noise emission level for fan model SFT 3113BK is 56 dB(A), which
represents alevel Aof acoustic power with respect to areference acoustic power of
1pW.
We reserve the right to change the text and technical specifications.
Safety class for electrical shock protection:
Class II – Electrical shock protection is provided by double or heavy-duty
insulation.
INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF
USED PACKAGING MATERIALS
Dispose of used packaging material at asite designated for waste in your municipality.
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT
This symbol on products or original documents means that used
electric or electronic products must not be added to ordinary
municipal waste. For proper disposal, renewal and recycling hand over
these appliances to determined collection points. Alternatively, in
some European Union states or other European countries you may
return your appliances to the local retailer when buying an equivalent
new appliance. Correct disposal of this product helps save valuable natural resources
and prevents potential negative effects on the environment and human health, which
could result from improper waste disposal. Ask your local authorities or collection
facility for more details. In accordance with national regulations penalties may be
imposed for the incorrect disposal of this type of waste.
For business entities in European Union states
If you want to dispose of electric or electronic appliances, ask your retailer or supplier
for the necessary information.
Disposal in other countries outside the European Union.
This symbol is valid in the European Union. If you wish to dispose of this product,
request the necessary information about the correct disposal method from the local
council or from your retailer.
This product meets all the basic requirements of EU directives related to
it.