Installation
Dimensions
HANDLE
CARTRIDGE
COVER
CAP
GRUB
SCREW
RETAINING
NUT
CARTRIDGE
FAUCET
SUPPLY LINES
RUBBER WASHER
PLASTIC WASHER
FEMALE SCREW
HEAD SCREW
7 3/8″
2 1/2″
6 3/4″
4 5/8″
5 1/4″
Unit:inches
2
1: Fit the washer into the underside of the faucet.
2: Screw the supply lines into the faucet and fully hand tighten.
3: Pass the tail of supply lines through the hole on the basin from above, and place the faucet in position on the basin, to see if any
alteration to the existing supply pipe work is necessary, make any necessary alterations to the pipe work.
4: Tighten the rubber washer, the plastic washer with the female screw from the underside of the counter.
5: Check that the faucet is correctly positioned, fully tighten the female screw.
6: Connect the water supply pipes to the tail of supply lines with the hot water and cold water.
This faucet meets or exceeds the following standards:
ASME A112.18.1/CSA B125.1/NSF61-9
This product has been tested and certified by IAPMO.
IAPMO LISTED
To remove the cartridge.
First shut off the water supply to the tap.
1: Pull out the cap from the handle.
2: Loosen the grub screw in handle, but do not remove it.
3: Take off the handle, unscrew the cartridge cover.
4: Unscrew the retaining nut.
5: Pull the cartridge and wash it with clean running water.
6: Dry and lightly grease the seals (only use silicone grease)