Performance Data Sheet
GE
Water by Culligan Filtration System
FXRC Cartridge
Health Claim Performance Certified by NSF/ANSI*
qO0% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent Effluent
Chlorine
T&O
Particulate**
MCL
Challenge
2.06 ppm
3,100,064
Average
O.14 ppm
519
Maximum
0.3 ppm
2425
% Reduction
Average Minimum
93 85
99.98 99.92
Parameter
T_bi_
Cys_
_ad_pH6.5
_ad_pH8.5
USEPA
MCL
1 NTU***
99.95 % Reduction
15 ppb
15 ppb
Standard No. 53: Health Effects
Influent Effluent
Average
0.10 NTU
92
3 ppb
3 ppb
Maximum
0.17NTU
179
3 ppb
3 ppb
Average
99.6
99.98
>98
>98
Challenge
23.25 NTU
494,169
157 ppb
162 ppb
% Reduction
Minimum
99.3
99.96
>98
>98
Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of Z 5 +_0.5; temp. of 20 ° +_Z5 ° C.
._.x.Measurement in Particles/m/
___NTU=Nephe/ometricTurbidityunits
Operating Specifications
Capacity: certified for up to 200 gallons (757 L)
Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
_Telnperamre: 33°-100 ° F. (0.6°-38 ° C.)
_Flow rate: 0.5 gpm (1.9 Lpm)
General Installation/Operation/Maintenance Requirements
Flush new caru'idge at fill flow for 60 seconds to purge out trapped air.
Replace cartridge when flow becomes too slow; at least eve U six months.
Special Notices
Installation instructions, parts and service availability, and standard warranty are included _dth tile product when shipped.
This drinking water systeln must be maintained according to lnanufilcmrer's instructions, including replacement of filter
cartridges.
Do not use where the water is lnicrobiologically unsafe, or with waters of unknown quali W without adequate disinfection
before or after tile systenl; systenl nlay be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treamlent system are not necessarily in your water.
Check for compliance with tile state and local laws and regulations.
NSF International Standards
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction, Class I
Mechanical Fihration Unit
Particulate Re&ration, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead Re(hmtion
Mechanical Fihration Unit
Cyst Re&lction
Turbidity Reduction
Tile Water by Culligan Fihration Sys[enl and FXRC cartridge have been
tested and Certified by NSF only for tile fimctions listed immediately above.
Made by: Culligan International, Westlnont, IL 60559, T: (630) 654-4000
General Electric, Appliance Park, Louisville, KY 40225 © 1997 GE
Tested & Certified
to ANSI/NSF
Standards 42 & 53