U-Line UBI98B00A ADA 1000 Series 15 Inch Black Freestanding Ice Maker

User Manual - Page 8

For UBI98B00A.

PDF File Manual, 13 pages, Read Online | Download pdf file

UBI98B00A photo
Loading ...
Loading ...
Loading ...
QUICK START GUIDE
5
u-line.com
4. On the back panel,
break away filler feature
in bushing, with flat
screwdriver.
5. Thread water line
through back panel hole
(with bushing).
6. Turn on water supply and check for leaks.
7. Reinstall back panel and grille/front access panel.
8. Install retaining clip.
REAR MOUNTED VALVE
PREPARE PLUMBING
Please use a braided stainless steel water supply line.
P/N (WATERHOOKUP).
CAUTION
!
Plumbing installation must observe all state and
local codes. All water and drain connections
MUST BE made by a licensed/qualified plumbing
contractor. Failure to follow recommendations
and instructions may result in damage and/or
harm.
Water Supply Connection
When connecting the water supply, please note the
following:
Before installing the unit and connecting to the cold
water supply, review the local plumbing codes.
The water pressure should be between 20 and 120 psi.
The water line MUST have a shut-off valve in the
supply line.
The water line should be looped into 2 coils. This will
allow the unit to be removed for cleaning and servicing.
However, make certain that the tubing is not pinched
or damaged during installation.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Remove
ZLWKɠDW
screwdriver
Loading ...
Loading ...
Loading ...