Installation Instructions
INSTALLING A J-MODEL IN AN EXISTING WALL CASE
Read these instructions completely and carefully.
[] REMOVE LOCKING PLATE ON
FRONT LEFT SIDE
Locking
plate
Remove
screw
[] REMOVE ALL SHIPPING PADS
(IF PRESENT) INSIDE AIR
CONDITIONER NEXT TO
COMPRESSOR
Remove
shipping
pads (if
present)
[] REINSTALL LOCKING PLATE WITH
TAB BEHIND WALL CASE FLANGE.
TIGHTEN SCREW
[] ATTACH POWER CORD TO BASE
PAN WITH CLAMP
pan
cord
P
[] ATTACH FRONT GRILLE
An opening for the power cord is on the
bottom of the front grille.
[] CAREFULLY SLIDE AIR
CONDITIONER BACK INTO CASE
Make sure that the tubing on the unit does
not touch the wall case and that the case
installation is secure.