Simer 4188 3/4 HP Zinc High Output Submersible Sump Pump

User Manual - Page 4

For 4188.

PDF File Manual, 28 pages, Read Online | Download pdf file

4188 photo
Loading ...
Loading ...
Loading ...
Installation 4
For parts or assistance, call Simer Customer Service at 800-468-7867
5. Power Supply: This pump requires a 115 V.,
60 Hz., 15 amp individual branch circuit.
The circuit must be grounded and should
be dedicated to the sump pump. The pump
is supplied with a 3-wire cord set with
grounding-type plug. Plug the switch directly
into the outlet and plug the pump into the
opposite end of the switch’s plug.
S
hock hazard. Always ground the
pump to a suitable electrical ground, such as a
grounded water pipe, a properly grounded
metallic raceway, or a ground wire system. Do
not cut off the round ground pin.
6. After you have installed the piping, check
valve, and float switch, the pump is ready for
operation.
Check the pump by filling the sump with water
and observing the pump’s operation through
one complete cycle. For switch settings see
Electrical and Switch Specifications.
Risk of flooding.
Failure to make
this operational check may lead to improper
operation, premature failure, and flooding.
Figure 5
6615 0712
6616 0712
Loading ...
Loading ...
Loading ...