Installation and Operation Manual - Columbia II
ENGLISH
8.1 Clearances
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA Canada USA
A
14 ½" (368 mm)
13" (330 mm)
A
7-1/2" (191 mm) 7-1/2" (191 mm)
B 10" (254 mm) 10" (254 mm) B 10" (254 mm) 10" (254 mm)
C 12" (305 mm) 12" (305 mm) C 12" (305 mm) 12" (305 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
13
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
D 18" (457 mm) 16 ½" (419 mm) D 11" (279 mm) 11" (279 mm)
E 19" (483 mm) 19" (483 mm) E 19" (483 mm) 19" (483 mm)
F 20 ¾" (527 mm) 20 ¾" (527 mm) F 20 ¾" (527 mm) 20 ¾" (527 mm)
8.1.1 With Heat Shield AC02710
14
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES FROM DOUBLE WALL PIPE
CONNECTOR
Canada USA Canada USA
A 2 ½" (64 mm) 2 ½" (64 mm) D 6" (152 mm) 6" (152 mm)
B 2 ½" (64 mm) 2 ½" (64 mm) E 11 ½" (292 mm) 11 ½" (292 mm)
C 2 ½" (64 mm) 2 ½" (64 mm) F 11 ¼" (286 mm) 11 ¼" (286 mm)
13
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
14
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certied with the single wall pipe
connector to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certied double
wall pipe connector can be used.