Bromic BH0420030 Heating Tungsten Smart-Heat 2000W Electric Heater

User Manual - Page 13

For BH0420030.

PDF File Manual, 16 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
13
www.bromic.com/heating
!
WARNING
This Heater MUST be permanently Installed and hard
wired by an authorised/licenced person. Do Not perform
maintenance, or carry out installation or assembly
procedure while electrical power is switched on.
1. Check product label for correct voltage and wattage.
Make sure power source conforms to the heaters
requirements.
2. Junction box has a 0.86” (22mm) to a standard 1/2
“weather tight conduit ttings. Install cord grip with
minimum rating of IPX4 to maintain the water ingress
protection rating of the heater. Cord grip must have
minimum temperature rating of 90°C (194°F). Failure to
install correctly will avoid the manufacturer’s warranty.
3. For supply connections, use suitable power supply wire
at least 90˚C (194˚F). Use Copper or aluminium wire. For
2000W Model: Use only on 15 Ampere branch circuit.
For 3000W Model: Use only on 20Ampere branch circuit
4. Make electrical connections in accordance with local
electrical code regulations. For outdoor installation all
connections must be made in accordance with local
electrical code regulations for outdoor wiring. Only
use wiring components approved for outdoor use with
minimum IPX4 rating. For 2000W & 3000W models
the junction box has one active and one neutral pig
WARNING
ELECTRICAL SHOCK HAZARD! Serious injury or death may
occur. Disconnect from electrical supply before installing or
servicing this heater. Read and follow installation clearance
requirements outlined in this manual. The Appliance MUST
be connected to a properly grounded electrical source.
!
ELECTRICAL INSTALLATION
tail. For 4000W & 6000W models the junction box
has the two marked and two unmarked pig tails. Use
the two marked pig tails for the rst element. Use the
two unmarked pig tails for the second elements. Earth
ground wire screw is located in the end of junction box
5. Assemble the junction box cover & gasket. Ensure that
the junction box cover gasket (supplied with unit) is
installed to maintain the IPX4 water ingress protection
rating of the heater. Failure to install correctly will void
the manufacturers warranty
ELECTRICAL INSTALLATION
5
1
2
4
Loading ...
Loading ...
Loading ...