6. Reconnect the stainless steel ex connector to the orice and ghten using (2) wrenches.
7. Place the burner back into the enclosure.
8. Fill out the conversion label included with your pao ame and apply it to the inside of the control
panel access door.

Natural Gas Hook-Up
The gas appliance is designed to operate at an inlet pressure of 7 inches water column. The piping up to
the appliance is the responsibility of the installer. Connect the inlet valve to rigid pipe, copper tube or an
approved exible metal connector, which complies with Z21.4/CSA 6.10. If using a gas hose (not supplied)
connect the ared end of the hose to the connector on the end of the inlet valve. Tighten using two
wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior to using the appliance. Piping
and valves upstream of the quick disconnect are not supplied. The gas supply pipe must be suciently
sized to supply the BTU/h specied on the rang plate, based on the length of the piping run. The quick
disconnect must not be installed in an upward direcon and a readily accessible manual shut-o valve
must be installed upstream of, and as close to, the quick disconnect as is feasible.

WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the appliance.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope
on any hose connecon.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
Locate the hose out of pathways where people may trip over it or in areas where the hose may be
subject to accidental damage.
Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons found
in the manual.