OPERATING WARNINGS
IMPORTANT: Remember to observe all safety warnings and precautions when operating
the heater on the automatic or timer modes, either attended or unattended since a fire
risk exists when the heater is accidentally covered or obstructed.
Mains cables are not provided with this heater.
CAUTION: Do not use if either of the heater’s mains power leads become damaged. If
the supply cord is damaged it must be replaced by the installer or an approved Dimplex
service partner.
Curtains must not come to within 250mm of the top of the heater.
Do not sit or stand on the heater.
Do not place objects in contact with the heater.
To maintain stability, it is essential that the heater is placed on a level surface and care
should be taken to avoid irregular surfaces, such as may result from carpets or tiled
surrounds partially protruding under the heater.
ELECTRICAL INSTALLATION
The installation of the heater should be carried out by trained personnel.
WARNING - Minimum clearances and IP zone requirements must be adhered to in
accordance with the current wiring regulations.
WARNING - The electrical installation of this heater must be carried out by a suitably
qualified or trained electrician, and be in strict accordance with current wiring Regulations.
The peak supply must be connected via a switched fused spur with a fuse rated suitably
for the appliances flex, the o-peak supply , via a 20A double pole switch. Failure to
follow these instructions will mean that the manufacturers instructions have not been
adhered to. THERE ARE NO EXCEPTIONS.
• This heater must be earthed
• Not suitable for connection via a plug top
• Do not locate the heater immediately above or below a fixed electrical point i.e. socket
outlet.
This appliance is intended for installation to a single phase supply only and is not suitable
for connection to 3 phase supplies.
The heater is not fitted with a mains cable, this should be fitted by the installer. Cable
type (minimum size) H05VV-F 1.5mm² three core for peak and 2.5mm² three core for
o-peak for connection to the fixed wiring of the premises through suitable isolation
devices positioned adjacent to the heater. The supply circuits to the heater must
incorporate a double pole isolating switch having a contact separation of at least 3mm.
In installation the supply cord must be cut to the appropriate length for the electrical
connection point. Excess cable should not be inserted or stored behind the heater.
If, during reassembly of the heater, a part of the thermal insulation shows damage or
deterioration, it should be replaced by an identical part.
WARNING: All electrical connections to the terminal block must be secure to prevent
risk of ignition. Tighten to 0.5 Nm.