OPERATION INSTRUCTION
Starting the unit
Allow the unit to stand upright for 24hrs to let the compressor stabilize
before use.
1. Firstly, turn the humidity control switch to the “OFF” position.
2. Plug in the dehumidifier.
3. Turn on the humidity control switch (clockwise) and turn the same switch to
the reading of the desired humidity (60% in general as shown on
position”4”).
Turning off the unit
1. Turn the humidity control switch fully anticlockwise to the “OFF” position and
the power supply is cut off and the unit stops operating.
2. If the dehumidifier is not in use for a long time, please disconnect the power
cord plug from the supply outlet.
NOTES AND PRECAUTIONS
1. The dehumidifier will not operate if the humidity setting is higher than the
ambient humidity.
2. When the water in the tank is full an automatic float switch shuts down the
product and the water level indicator light illuminates. Remove the water
storage tank and empty its contents, carefully replace the empty water tank
back in position, the unit will now automatically restart operating.
3. When the unit stops, you have to wait for 3 minutes before you can
restart the unit to protect the compressor from damage.
4. The following table indicates the approximate relative humidity setting
against its related position number on the humidity control switch:
CONTROL SWITCH
POSITION NO.
APPROXIMATE
HUMIDITY SETTING
8
20
7
30
6
40
4
60
2
80
Loading ...
Loading ...