OceanAire PWC1811 18,000 BTU Portable Water-Cooled Air Conditioner

ENGINEERING, INSTALLATION AND SERVICE MANUAL - Page 5

For PWC1811. Series: PWC series
Also, The document are for others OceanAire models: PWC60*, PWC12*

PDF File Manual, 32 pages, Read Online | Download pdf file

PWC1811 photo
Loading ...
Loading ...
Loading ...
STANDARD FEATURES
CABINET
The PWC-Series cabinet is constructed of 18 gauge steel with a gray polyester powder
coated finish that will compliment any decor. The entire cabinet is insulated with
sound- absorbing insulation for cool, quiet comfort. All units come equipped with handles
and swivel casters for portability and convenient set-up.
ELECTRONIC THERMOSTAT
All PWC units are equipped with a non-programmable electronic thermostat. When
power is connected to the unit, the thermostat will control the unit to cool a space to the
desired temperature. The thermostat is also capable of controlling the fan to operate
automatically (when needed) or continuously. To protect the compressor from
short-cycling, there is a built-in time delay in the thermostat. In the event of a power
outage, all thermostat settings are saved, and the unit will re-start automatically.
FAN SPEED CONTROL
A two position rocker switch, located next to the thermostat, provides the user with the
option of running the evaporator fan at high-speed or low-speed.
CONDENSATE PUMP
All PWC units come equipped with an Automatic Condensate Pump that removes the
condensate. The pump discharges through a 3/8 male flare connection located on the
back of the unit. The pump is capable of pumping to a 20-foot height, to handle almost
any installation requirement.
CONDENSATE ALARM LIGHT
On the front of all PWC models, there is a Condensate Alarm Light (RED) located near
the thermostat. The light indicates a condensate pump over-flow condition where the
pump is either disabled, or incapable of removing the condensate water, and must be
serviced.
FILTERS
All PWC units are equipped with a washable filter at the air intake. An electrostatic mesh
air filter is located behind the evaporator return air grille to filter the air before it is cooled,
keeping the coil free from dust build-up. The filter can be easily removed and cleaned.
HIGH PRESSURE SAFETY SWITCH
Located on the back of the PWC unit is a manual re-set high pressure switch, used for the
protection of the compressor in the event that the condenser water supply is turned off. If
the condensing pressure exceeds the limit setting, the switch cycles off the compressor,
while the evaporator fan remains running, The high pressure switch is also wired in se-
ries with the condensate pump. If a failure occurs with the operation of the pump
circuit, the HP switch will open. Once the water interruption/condensate pump failure has
been corrected, turn the unit off, reset the switch by depressing the red
RESET button on the back of the unit, and restart the unit.
POWER CORDS
All PWC units come with power cords, convenient connection and portability. All models,
except for the 3-phase and 5-ton units, are equipped with LCDI for added safety devices.