VENTING THE PELLET STOVE
Do not install flue damper in the exhaust
venting system of this unit.
Use an approved wall thimble when
passing the vent through walls. Use a
ceiling support/fire stop spacer when
passing the vent through ceilings. (Make
sure to maintain minimum clearances to
combustibles)
If using more than one T-vent or exceed
180° of elbows, you must use 4" venting
pipe.
NOTE: In order to achieve optimum
performance, it is recommended that you keep
the vent as short as possible, especially in
regards to the horizontal run.
The vent must have a support bracket
every 5' of pellet vent when on the exterior
of the structure.
The vent height and run must not exceed
the distance as illustrated in diagram
Figure 9.
Venting into the lighter shaded area may
require combustion motor voltage
adjustments and/or inlet air adjustments
(intake).
See Figure 9
Figure 9: Venting and combustion motor
voltage adjustment chart