16.1 Indoor Unit Error Display
Operation
lamp
Timer lamp Display LED STATUS
1 time
X
E0 Indoor unit EEPROM parameter error
2 times
X
E1
Communication malfunction between indoor and
outdoor units
4 times
X
E3 Indoor fan speed has been out of control
5 times
X
E4 Indoor room temperature sensor (T1 ) malfunction
6 times
X
E5 Evaporator coil temperature sensor (T2) malfunction
7 times
X
EC Refrigerant leakage detection
8 times
X
EE Water-level alarm malfunction
1 time
O F0 Current overload protection
2 times O F1 Outdoor ambient temperature sensor (T4 ) malfunction
3 times
O
F2 Condenser coil temperature sensor (T3) malfunction
4 times
O
F3
Compressor discharge temperature sensor (T5)
malfunction
5 times
O
F4 Outdoor unit EEPROM parameter error
6 times
O
F5 Outdoor fan speed has been out of control
7 times
O F6
Indoor coil outlet pipe sensor(Located on outdoor unit
low pressure valve)
8 times
O F7
Communication malfunction between Cassette optional
lift panel and the unit
9 times
O F8 Cassette optional lift panel malfunction
10 times
O F9 Cassette optional lift panel not closed
1 times
P0 Inverter module (IPM) malfunction
2 times
P1 Over-voltage or under-voltage protection
3 times
P2 Compressor top high temperature protection (OLP)
4 times
P3 Low ambient temperature cut off in heating
5 times
P4 Compressor drive malfunction
6 times
P5 Indoor units mode conflict
7 times
P6 Low pressure protection
8 times
P7 Outdoor IPM temperature sensor error