1. The cold incoming water is heated
instantaneously as it ows over the heating
elements in the heat exchanger assembly.
2. At the start up the shower will reach
temperature in 20–30 seconds.
3. The amount of hot water available at the set
temperature is limited by the total power of
the heater.
4. The water is turned on and off by the
solenoid valve built into the shower.
5. A stabilizer built into the water ow valve
automatically compensates for small
uctuations in water pressure that frequently
occur in households.
6. A thermal cut-out is mounted on top of the
heat exchanger.
Stage 1 switches the power off to the
elements if it senses an excessive
temperature. The switch operates with an
audible click and will re-set if cold water is
run through the shower.
Stage 2 only operates if an extreme
temperature is sensed. The cut-out will
permanently switch off and will then have to
be replaced.
7. A pressure relief device is tted to the
bottom of the heat exchanger body to
safeguard against a build up of pressure
in the heater. It provides protection to the
heater should there be an excessive build
up of pressure occur. If this device operates
then a replacement part will be required.
ATTENTION!
Do not operate the shower unit if the shower head or hose becomes damaged. The shower is
designed and approved to EN-60335 with the shower head provided. Under no circumstances
must any shower head that is not approved by the manufacturer be used with this product also
never t any additional device to restrict the water ow.
SHOWER HANDSET CLEANING
INSTRUCTIONS
The shower handset should be cleaned
periodically to remove lime scale or debris
which will reduce the performance of the
shower. The frequency of the cleaning will vary
according to local water quality.
Place shower handset in
de-scale soultion.
User Guide
1 2
Rinse shower handset
with water.
FILTER CLEANING INSTRUCTIONS
It is recommended that the lter is periodically
cleaned in order to maintain the performance of
the shower. It is essential that this operation is
carried out by a competent person.
IMPORTANT: Before servicing, switch off the
electricity supply at the isolation switch.
Switch off the mains water supply at the
isolation valve.
The inlet lter is situated inside the water
inlet housing.
To gain access unscrew the lter cap from
the bottom of the inlet housing.
Inspect o-ring for damage when the lter cap
is removed.
To reassemble, follow procedure in reverse.
DO NOT over tighten the lter cap on
reassembly.