RadonAway RP140C RP140 Radon Mitigation Fan

User Manual - Page 2

For RP140C.

PDF File Manual, 8 pages, Read Online | Download pdf file

RP140C photo
Loading ...
IN096 Rev A 0718 23 Saber Way Ward, Hill, MA 01835 | radonaway.com
Fan Installation & Operating Instructions
RPc, GP,c XPc, XR Series Fans
Please Read and Save These Instructions.
DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN.
1. WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials,
Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications.
RadonAway.com/vapor-intrusion
2. NOTE: Fan is suitable for use with solid state speed controls; however, use of speed controls is not
generally recommended.
2. WARNING! Check voltage at the fan to insure it corresponds with nameplate.
3. WARNING! Normal operation of this device may affect the combustion airow needed for safe operation of fuel
burning equipment. Check for possible backdraft conditions on all combustion devices after installation.
4. NOTICE! There are no user serviceable parts located inside the fan unit.
Do NOT attempt to open. Return unit to the factory. (See Warranty, p. 8, for details.)
5. WARNING! Do not leave fan unit installed on system piping without electrical power for more than 48 hours. Fan
failure could result from this non-operational storage.
6. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer. (See p. 8.)
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
c) Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable
codes and standards, including re rated construction.
d) Sufcient air is needed for proper combustion and exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the heating equipment manufacturers’ guidelines
and safety standards such as those published by any National Fire Protection Association, and the
American Society for Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
e) When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
f) Ducted fans must always be vented to outdoors.
g) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and
be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.