5
Back View
Optional Full-Width Duct Cover Installations
Installation Dimensions
IMPORTANT:
Minimum distance “X”: 24" (61 cm) from electric cooking
surfaces
Minimum distance “X”: 30" (76.2 cm) from gas cooking
surfaces
Suggested maximum distance “X”: 36" (91.4 cm)
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide ef cient performance.
For the most ef cient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than one elbow is used.
Do not install two elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the cap has a
damper, do not use the damper supplied with the range
hood.
Use caulking to seal exterior wall or roof opening around
thecap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air ow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than speci ed CFM of
air movement. The speci ed CFM varies from locale to locale.
Consult your HVAC professional for speci c requirements in
yourarea.
Venting Methods
Typical Internal Blower Motor System Venting Installations
A 10" (25.4 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 10" (25.4 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall.
A. Knockout into terminal box
B. Top of hood
C. Wood support
D. Bottom of hood
A
B
C
CL
(45.7 cm)
18"
D
18 " (47.8 cm) for 48" (121.9 cm) Hood
12 " (32.5 cm) for 36" (91.4 cm) Hood
(24.4 cm)
9 "
13
/
16
13
/
16
5
/
8
A. Optional full-width duct cover
B. Range hood
12"
(30.5 cm)
(45.7 cm)
12"
18"
(30.5 cm)
A
B
13" (33.0 cm )
18" (45.7 cm) min.
clearance upper
cabinet to countertop
36" (91.4 cm)
countertop height
36.06" (91.6 cm), or 48.07" (122.1 cm)
cabinet opening width
(If installed between cabinets)
X
Bottom of Range hood
to cooking surface
Full-Width
Duct Cover (if used)
Min. cabinet
opening width
Range Hood
12" (30.5 cm)
A
B
A
B
B
A
Wall Venting
Roof Venting
Wall Venting
A. Roof cap
B. 10" (25.4 cm)
round vent
A. Wall cap
B. 10" (25.4 cm)
round vent
A. Wall cap
B. 10" (25.4 cm)
round vent