5. SPECIFICATIONS
Nominal input voltage .....................................................................12.8-13.2 VDC
Nominal output voltage .................................................................... 110-125 VAC
Output frequency ...............................................................................60 Hz ± 3 Hz
Operating input voltage .................................................................. 10.5-15.5 VDC
Continuous output power ................................................................ Up to 1500 W
Surge output power (0.1 second) .............................................................. 3000 W
Waveform ................................................................................Modified sine wave
Maximum efficiency ........................................................................................ 90%
Maximum no load current (at nominal input voltage)............................ 0.80 ADC
Input overvoltage shutdown ............................................................. 16 ± 0.5 VDC
Input undervoltage alarm .............................................................. 10.5 ± 0.5 VDC
Input low voltage shutdown ............................................................. 10 ± 0.5 VDC
Output power overload shutdown level .......................................... 1675 ± 175 W
Internal fuse ............................................................................................... 30A x 6
AC receptacles ....................................................................Two, NEMA 5-15 USA
USB ports ...................................................................................................Two, 2A
Battery cables ......................................................................... One black, one red
Ground wire ........................................................................................... One green
6. REPLACEMENT PARTS
Battery cable (black) ........................................................................ 3899003409Z
Battery cable (red) ........................................................................... 3899003410Z
7. BEFORE USING YOUR CONVERTER
Do not use the converter with a product
that draws a higher wattage than the
converter can provide, as this may cause
damage to the converter and product.
When you turn on a device or a tool that
runs on a motor, the device goes through
two stages:
1.
Start Up – Requiring an initial surge of
power (commonly known as the “start-
ing” or “peak” load).
2.
Continuous Operation – Power con-
sumption drops (commonly known as
the “continuous load”).
The wattage (WATTS) or amperes (AMPS)
can normally be found stamped or printed
on most devices and equipment, or in
the user’s manual. Otherwise, contact
the manufacturer to find out whether the
device you want to use is compatible with
a modified sine wave.
To calculate the wattage:
Wattage = AMPS x 120 (AC Voltage).
To calculate the starting load:
Starting Load = 2 x wattage.
In general, the startup load of the device
or power tool determines whether your
converter has the capability to power it.
To calculate the continuous load:
Continuous Load = AMPS x 120