Technical Data
Heat Pump Cylinder Range - Dimensions
Reference
125
150
175
210
250
300
Weight [kg]
30
35
38
42
47
53
Reheat time [mins]*
7
7
11
12
17
20
Average draw off temperature
[°C]*
61
60
63
62
63
62
Hot water draw off capacity (l)*
/ draw off flow rate (l/s)
97
120
142
180
238
267
0.25
0.25
0.25
0.25
0.25
0.50
Heat loss [kWh]*
0.95
1.10
1.12
1.41
1.51
1.96
Height [mm]
945
1115
1265
1490
1765
2065
Outer Diameter [mm]
580
580
580
580
580
580
HW Outlet [mm]
720
890
1040
1265
1540
1840
T&P Valve [mm]
720
890
1040
1265
1540
1840
Secondary Return [mm]
-
-
-
957
1095
1245
CW Inlet [mm]
180
180
180
180
180
180
Bottom Immersion [mm]
200
200
200
200
200
200
HP Return [mm]
180
180
180
180
180
180
HP Flow [mm]
700
835
835
885
885
920
Bottom Thermostat [mm]
450
535
610
722
860
1010
Table 4: Heat Pump Cylinder Dimensions
Note: All measurements are taken from the base of the cylinder to the mid-point on the item.
* Determined in accordance with EN12897 at 80°C flow temperature and 0.42l/s flow rate.
GDC Group Ltd
Heat Pump Cylinder Range Product Fiche
Reference
Efficiency Class
Standing Loss [W]
Actual Capacity [L]
ECS125HP-580
B
40
117
ECS150HP-580
B
54
142
ECS175HP-580
B
56
174
ECS210HP-580
B
59
200
ECS250HP-580
B
66
245
ECS300HP-580
C
82
292
Table 5: Heat Pump Product Fiche