Installation
HP Installatio
n and User Instructions R00918
-10 09/15
Page
26
Step 3: Move the sensor mounting plate back into its fixing position. Be careful not to
kink the capillaries that connect the thermostat bulbs. Fit the four M5 fixing screws into
the cylinder bracket (F). Tighten the screws until the thermostat bulbs and heat pump
sensor are held firmly against the wall of the inner cylinder.
Note: there should be no movement in the phials that are used to hold the bulbs and
sensor. Care should be taken not to overtighten the screws.
Step 4: Replace the insulating foam over the sensor mounting plate.