Pioneer WYS050GMHI22M5 Air Conditioner

User Manual - Page 74

For WYS050GMHI22M5. Also, The document are for others Pioneer models: YN020GMFI22M2D,   YN030GMFI22M3D, YN040GMFI22M4D, YN050GMFI22M5D

PDF File Manual, 82 pages, Read Online | Download pdf file

WYS050GMHI22M5 photo
Loading ...
Loading ...
Loading ...
8.4.2.15 The cooling operation or heating operation does not operate.
Supposed causes
4-way valve faulty
Check of 4-way valve, please refer to part 5 in 9.5 Trouble Criterion of Main Parts.
8.4.2.16 When cooling, heat exchanger of non-operating indoor unit frosts.
When heating, non-operating indoor unit get warm.
Supposed causes
EXV faulty
Wire and tubing connected in reverse.
Check of EXV, please refer to part 6 in 9.5 Trouble Criterion of Main Parts.
8.5 Trouble Criterion of Main Parts.
Spec.
Outdoor unit
Model YN020GLFI22M2D YN030GLFI22M3D YN040GLFI22M4D YN050GLFI22M5D
Compressor
ATM150D23UFZ ATF235D22UMT ATF310D43UMT ATQ360D1UMU
Outdoor fan motor
ZKFN-50-8-2 ZKFN-120-8-2 ZKFN-120-8-2 ZKFN-85-8-22
Temperature sensor checking
Disconnect the temperature sensor from PCB, measure the resistance value with a tester.
Temperature Sensors.
Room temp.(T1) sensor,
Indoor coil temp.(T2) sensor,
Outdoor coil temp.(T3) sensor,
Outdoor ambient temp.(T4) sensor,
Compressor discharge temp.(T5) sensor.
Measure the resistance value of each winding by using the multi-meter.
Loading ...
Loading ...