Page 29
Installation and Operation Manual - Escape 2100
ENGLISH
8.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
A 11" (279 mm) 11" (279 mm) D 15 ¾" (400 mm) 15 ¾" (400 mm)
B 16" (406 mm) 16" (406 mm) E
26 " (683 mm) 26 " (683 mm)
C 10" (254 mm) 10" (254 mm) F 20 ¾" (527 mm) 20 ¾" (527 mm)
L 72" (1,830 mm) 72" (1,830 mm)
8.1.3 With Heat Shield AC02710 or AC02762 and Lowered Ceiling
16
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
A 2 ½" (64 mm) 2 ½" (64 mm) D 7 ¼" (184 mm) 7 ¼" (184 mm)
B 2 ½" (64 mm) 2 ½" (64 mm) E
13 " (340 mm) 13 " (340 mm)
C 2 ½" (64 mm) 2 ½" (64 mm) F 13 ¼" (337 mm) 13 ¼" (337 mm)
L 74" (1,880 mm) 74" (1,880 mm)
8.1.4 Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
A
11" (279 mm) 11" (279 mm)
D
15 ¾" (400 mm) 15 ¾" (400 mm)
B
16" (406 mm) 16" (406 mm)
E
26 " (683 mm) 26 " (683 mm)
K
48" (1220 mm) 36" (910 mm)
L 74" (1,880 mm) 74" (1,880 mm)
15
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certied with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certied double wall
pipe connector can be used.
16
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.