Loading ...
Loading ...
Loading ...
10
EN
SAFETY INSTRUCTIONS
Never attach the fan to a power point,but to the ceiling itself.
The minimum distance between the blades of the fan and the oor must be more
than 2.3 m.The minimum carrying capacity of the hook from which the fan is hung
must be 100 kg.
Make sure to install all poles disconnection switch having a contact separation of at
least 3 mm between poles in the supply wiring to the ceiling fan.
The model or type reference of luminaries which may be installed in fans which are
constructed for his purpose.
Switch off the power before connecting.
The electrical wiring must be in accordance with the local regulation.
The fan must be properly earthed to avoid the risk of electric shocks.
Never mount the fan in a moist or wet room.
Be careful when working near the rotating blades.
Note: Always have your fan installed by someone who is knowledgeable about
electrical wiring.
INSTALLATION
1 2 3
Secure the mounting plate
to a ceiling joist with two
screws, spring washers
and at washers provided.
Ensure the support for
the mounting plate must
be capable of safely
and securely holding the
moving weight of the fan.
Hang the fan assembly
onto the mounting plate.
The mounting plate has
a lug on it; this should
be lined up with the
corresponding groove on
the fan assembly ball joint.
Insert the remote control
receiver between the bra-
cket and the ball joint, and
the sensor as shown.
Loading ...
Loading ...
Loading ...