Napoleon GDIX3N Oakville X3 Gas fireplace insert

User Manual - Page 13

For GDIX3N. Series: Oakville™ Series

PDF File Manual, 56 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
EN
W415-1867 / D / 02.25.20
13
5.0 remote control layout
5.2 split ow (GDIX4 only)
Low battery alarm
Key Lock
Room
Temperature
Light
Flame ON
Blower
Transmission
CPI mode
Split Flow
The split fl ow function controls the ability to turn ON /
OFF a second burner.
1. Use the mode key to guide you to the split
ow function.
2. Pressing the up arrow key will activate the
second burner.
3. Pressing the down arrow key will deactivate
the second burner. A single “beep” will
confi rm the reception of the command.
note:
This is no way to modulate the flame heights separately.
76
°F
OFF
76
°F
ON
5.3 initializing the transmitter / battery holder for the fi rst time
A. Install the 4 AA batteries into the Profl ame 2 battery holder, note the polarity of the batteries and insert as
indicated on the cover (+/-).
B. Ensure the 3 position slider switch is switched to the “REMOTE” position (middle position).
C. Press the reset/programming button, use a small object such as a paper clip in order to reach the button
marked PRG, as shown in the illustration below.
D. The battery holder will beep 3 times to indicate that it’s ready to synchronize with the transmitter.
E. Install the 3 AAA batteries into the transmitter, as shown in the photograph below, then press the ON
button, The battery holder will beep 4 times to indicate that the transmitter’s command is accepted.
note:
The initializing process must be completed within 10 seconds of pressing the reset/program button (PRG).
(4) AA Batteries
TRANSMITTER
RESET/PROGRAM
BUTTON (PRG)
BATTERY HOLDER
SLIDER SWITCH
5.1 general transmitter layout