IN096 Rev A 0718 73 Saber Way, Ward Hill, MA 01835 | radonaway.com
Typical CFM Vs. Static Pressure “WC
1.0” 1.5” 2.0” 2.5” 3.0” 3.5” 4.0”
GP301c 64 54 41 4 - - -
GP501c - - 66 58 50 27 4
Model Size Weight Inlet/Outlet
GP301c 13”H x 12.5” Dia. 12 lbs 3.5” OD
GP501c 13”H x 12.5” Dia. 12 lbs 3.5” OD
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
GP301c 56-100 watts 2.3” WC
GP501c 68 - 146 watts 3.8” WC
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
GPc Series Product Specications
Typical CFM Vs. Static Pressure “WC
Model 0” .25” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0”
RP140c 135 103 70 14 - - - -
RP145c 166 146 126 104 82 61 41 21 3
RP260c 251 209 157 117 70 26 - - -
RP265c 334 291 247 210 176 142 116 87 52
Model Recommended Duct PVC Pipe Mounting Thermal Cutout Insulation Class
RP140c
3” or 4” Schedule
20/40 PVC
Mount on the duct pipe or with
optional mounting bracket.
For Ventilation: 4”, 6” or 8” Rigid
or Flexible Ducting.
130
o
C/266
o
F Class B Insulation
RP145c 130
o
C/266
o
F
Class F InsulationRP260c 150
o
C/302
o
F
RP265c 150
o
C/302
o
F
XP201c
3” or 4” Schedule
20/40 PVC
Fan may be mounted on the duct
pipe or with integral anges.
120
o
C/248
o
F Class B Insulation
XR261
GP301c
3” or 4” Schedule
20/40 PVC
Fan may be mounted on the duct
pipe or with integral anges.
120
o
C/248
o
F Class B Insulation
GP501c
RPc, XPc, XR and GPc Series Additional Specications
Continuous Duty
3000 RPM
Thermally Protected
RPc, GPc Residential and Commercial
XPc, XR Residential Only
Rated for Indoor or Outdoor Use
Loading ...