Loading ...
Loading ...
Loading ...
Exhaust hose
Window ex-
haust adapter
Projection
Extend
Hole
"TOP"
E-14
The exhaust hose must be installed or removed in accordance with the usage mode.
MODE EXHAUST HOSE
COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container Install
DEHUMIDIFICATION with container(minimum capacity 3
1
/
2
gallons) Remove
Installation of the exhaust hose
1
Attach the window exhaust adapter to
the exhaust hose.
Extend one end of the exhaust hose
and insert it into the window exhaust
adapter, and turn it (approx. three times)
until it stops.
Make sure they are securely attached.
2
Attach the exhaust hose adapter to
the unit.
Insert the two projections on the ex-
haust hose adapter into the two holes
on the unit, and rmly attach them to
each other.
3
Slide and open the exhaust cover on
the window panel, and attach the win-
dow exhaust adapter.
Surface of window exhaust adapter
marked "TOP" should be at the top
when it is installed in a double-hung
sash window.
Surface of window exhaust adapter
marked "TOP" should be on the window
frame side when it is installed in a
sliding sash window.
The exhaust hose should be as short as possible for operational ef ciency;
however, it must not be twisted or bent.
Unacceptable
Acceptable
Acceptable
INSTALLATION AND REMOVAL OF EXHAUST HOSE
Loading ...
Loading ...
Loading ...