EN7
Connection to the terminal block
For the electrical connection of the power cord is present in the supply. Follow the instructions below.
Connect the ground cable yellow / green to terminal symbol .
1. Remove the terminal cover (A) by unscrewing the screw and insert the cover into the hinge (B) of the terminal.
2. Plug the power cord into the clamp and connect the wires to the terminal block as shown in the wiring diagram located near the terminal.
3. Secure the power cable with the cable clamp.
4. Close the cover (C) and screw on the terminal with the screw removed.
For each connection to the network, the hob automatically checks for a few seconds.
ELECTRICAL CONNECTION
WARNING
- Disconnect the appliance from the power supply.
- Installation must be carried out by qualified personnel who know the current safety and
installation regulations.
- The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the regulations
provided in this chapter.
- The power cable must be long enough to allow the hob to be removed from the worktop.
- Make sure the voltage specified on the dataplate located on the bottom of the appliance is the same as that of the home.
CBA
Colour Grey
Colour Blue
Colours Brown
Colour Black
Colour Yellow-Green
N1 N2L1 L2E N1 N2L1 L2E
N1 N2L1 L2E N1 N2L1 L2E
L1
L2
N2
N1
N
380-415V
380-415V
220-240V
220-240V 380-415V
220-240V
230-240V