INSTALLATION
WARNING! Refer to Safety chapters.
POSITIONING
This appliance can be installed in a dry, well
ventilated indoor where the ambient temperature
corresponds to the climate class indicated on the
rating plate of the appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
ELECTRICAL CONNECTION
CAUTION! Any electrical work
required to install this appliance
should be carried out by a qualified
electrician or competent person.
WARNING! This appliance must be
earthed.
The manufacturer declines any liability
should these safety measures not be
observed.
The wires in the mains lead are coloured in
accordance with the following code:
A B
C
D
E
A - green and yellow: Earth
C - brown: Live
D - blue: Neutral
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
1. Connect the wire coloured green and yellow to
the terminal marked either with the letter “E“ or
by the earth symbol or coloured green and
yellow.
2. Connect the wire coloured blue to the terminal
either marked with the letter “N“ or coloured
black.
3. Connect the wire coloured brown to the
terminal either marked with the “L“ or coloured
red.
4. Check that no cut, or stray strands of wire is
present and the cord clamp (E) is secure over
the outer sheath.
Make sure the electricity supply voltage is the
same as that indicated on the appliance rating
plate.
5. Switch on the appliance.
The appliance is supplied with a 13 amp fuse (B).
In the event of having to change the fuse in the plug
supplied, a 13 amp ASTA approved (BS 1362)
fuse must be used.
WARNING! A cut off plug inserted
into a 13 amp socket is a serious
safety (shock) hazard. Ensure that it is
disposed of safely.