20
Technical Data
Door lock
problem
Door is not closed properly.
Restart after the door is closed.
Reason
Solution
Description
Display
LED
Please call up service line if there are still troubles.
Drain problem
while washing
Water injecting
problem while
washing
Tap is not opened or water
flows too slowly.
Inlet valve filter is blocked.
Inlet pipe is twisted.
If water is not supplied
Open the tap or wait till the
water supply becomes normal.
Check inlet valve filter.
Straighten the water pipe
Check the other taps in the
room.
Please call up service line if there are still trouble
s.
Please call up service line if there are still troubles.
Outlet hose is blocked or twisted
Drain pump is blocked
Wash and straighten outlet hose.
Wash drain pump filter
Please call up the service line if there is any other problem.
P.28
You can find relevant information via the email:XXX@midea.com.cn
P.29
Wuxi Little Swan Co., Ltd.
No.18 ChangJiang South Road, Wuxi City, Jiangsu Province, China
Dimension(W* D* H)
Net Weight
Rated Power
MAX.Current
Standard Water Pressure
Washing Capacity
Power Supply
595*565*850
72kg
1950W
10A
0.05MPa~1MPa
9.0kg
220-240V~,50Hz
Product Specifications
ADDITIONAL INFORMATION FOR Standard performance TESTING:
(AS/NZS 2040.1:2005+Amdt1-2007+Amdt2-2009)
1. Water connections:Cold & hot water connection
2. Water supply pressure: 320 kPa
3. Warm wash Program: Cotton 60Display: 4:46
Cold wash program: Cotton Cold( no temperature display is cold wash)
4. Detergent type: Drum detergent
5. Detergent quantity: Default
6. Adding detergent:
The detergent is dissolved and added as Paragraph B7.3 of AS/NZS 2040.1
The detergent s
hall be dissolved in 1 L of water
7. Anti-sudsing agent: Max
8. Test load mass: 9.0kg
9. Water consumption: L
10.Test Voltage:220-240V~,50Hz