Loading ...
Loading ...
3
Location Requirements
You will need
A location that allows for proper exhaust installation. A gas
dryer must be exhausted to the outdoors. See Venting
Requirements.
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See Electrical Requirements.
A sturdy floor to support the dryer and a total weight (dryer
and load) of 200 lbs (90.7 kg). The combined weight of a
companion appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet kit, Part No. 279810.) Clothes may not tumble
properly and models with automatic sensor cycles may not
operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
*Most installations require a minimum 5½" (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See Venting
Requirements.
Minimum installation spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
A. Small Opening Side-Swing Door
B. Large Opening Side-Swing Door
C. Wide Opening Side-Swing Door
D. Wide Opening Hamper Door
43³⁄₈"
(
110cm)
*26"
(66cm)
29"
(73.66cm)
A
15¼"
(38.74cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
B
22¾"
(57.8cm)
43³⁄₈"
(110cm)
13¾"
(34.9cm
)
*27¾"
(70.5cm)
29"
(73.66cm)
D
43³⁄₈"
(
110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
C
22¾"
(57.8cm)
Loading ...
Loading ...
Loading ...