180
PRIUS PRIME_OM_OM47D13U_(U)
2-2. Charging
Charging starts immediately, even though charge schedule is registered
“Charge Now” is set to “On”
When charging according to the
timer, set “Charge Now” to “Off”.
(P. 163, 172)
Charge schedule is set to “Off”
Check that charge schedule is not
set to “Off”. (P. 161, 171)
Charging mode is set to “Departure”
and schedule departure time is
close to current time
When the system determines that
there is no time to finish charging by
the set scheduled departure time, it
starts charging immediately. Check
the charge schedules.
Charging cable was removed and
reinserted while charging indicator
was flashing
If the charging cable is removed and
reinserted while the charging indica-
tor is flashing, the charging timer is
canceled (P. 146). Temporarily
remove the charging cable, and then
reconnect it.
The Remote Air Conditioning Sys-
tem was operated
When the Remote Air Conditioning
System is operated, the system will
start charging immediately, even if
the charge schedule is registered.
To carry out charging using the
timer, stop the Remote Air Condi-
tioning System, and then reconnect
the charging cable.
“Traction Battery Heater” (P. 132)
operated
When the charging mode is set to
“Departure”, “Traction Battery
Heater” may operate before
charging starts. Check the status of
the charging indicator. (P. 112)
Outside temperature is low and
hybrid battery (traction battery)
warming control (P. 133) of the
hybrid battery (traction battery) oper-
ated
(Alaska and Canada only)
When hybrid battery (traction bat-
tery) warming control of the hybrid
battery (traction battery) operates,
the timer settings are ignored and
charging starts immediately. In order
to protect the hybrid battery (traction
battery), allow charging to continue.
Likely cause Correction procedure