5. To mount the filters back follow the
first two steps in reverse order.
Repeat the steps for all filters if
applicable.
6.2 Replacing the charcoal
filter
WARNING!
The charcoal filter is non-
washable!
The time of saturation of the charcoal
filter varies depending on the type of
cooking and the regularity of cleaning
the grease filter.
To replace the filter:
1. Remove the grease filters from the
appliance.
Refer to "Cleaning the grease filter" in
this chapter.
2. Remove the clips holding the filter
bed, then the filter bed.
3. To install a new filter, perform the
same steps in reverse order.
In any case, it is necessary to replace the
filters at least every four months.
6.3 Replacing the lamp
This appliance is supplied with a LED
lamp. This part can be replaced by a
technician only. In case of any
malfunction refer to "Service" in the
"Safety Instructions" chapter.
7. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
7.1 What to do if...
Problem Possible cause Remedy
You cannot activate the ap-
pliance.
The appliance is not connec-
ted to a power supply or it is
connected incorrectly.
Check if the appliance is cor-
rectly connected to the elec-
trical supply.
You cannot activate the ap-
pliance.
The fuse is blown. Make sure that the fuse is
the cause of the malfunction.
If the fuse is blown again
and again, contact a quali-
fied electrician.
The lamp does not operate. The lamp is defective. Replace the lamp. Refer to
the "Care and Cleaning"
chapter
The appliance does not ab-
sorb enough vapours.
The motor speed is not ade-
quate to the appearing va-
pours.
Change the speed of the
motor.
www.aeg.com8