Features and appearance will vary. Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
NOTE: When the bucket is full or removed, the controls cannot be set.
1. Power Pad
Turns air conditioner on and off. When turned on, the display will show the room temperature.
2. Display
Shows the room temperature. Shows the Set temperature while setting the temperature in Cool or ECO modes. The Set light will turn on while setting.
3. Temp Increase + /Decrease - Pads
Use to set temparature when in Cool or ECO mood. The set light will turn on while setting.
4. Fan Speed Pads
Use to set the fan speed to Low, Med or High or Auto on the unit.
NOTE: On the remote control, use the fan speed Increase + /
Decrease – pads to set the fan speeds to Low, Med or High.
Use the Auto pad to turn Auto fan on.
5. Mode Pad
Use to set the air conditioner to Cool, ECO or Fan Only mode.
6. WiFI
Enables connection of the air conditioner to the home WiFi.
Download App for details at GEAppliances.com/connect.
7. Reset Filter
LED will turn on when fan has accumulated 250 hours of run time as a reminder to clean filter. Press Reset Filter to turn off the LED and reset the accumulated run time.
NOTE: The default temperature reading on the display is degree Fahrenheit ( °F). To change the display to degree
Celsius (°C), press the Temp Increase + and Temp Decrease - buttons together and hold for 3 seconds. Repeat the process to change back to degree Fahrenheit (°F)
8. Control Display On and Off
To reduce brightness during sleeping hours, this air conditioner control display has an automatic off feature where the control display will turn off completely after 5 minute of inactivity. To illuminate the control interface, press any button on the control display or remote control. The control display will illuminate all previously illuminated LED’s. The control interface will now respond to any prescribed button press after it is illuminated.
Press and hold the FAN+MODE button for 3 seconds to toggle this feature ON or OFF. The LED’s will now stay ON anytime the unit is ON.
9. Control sound on/off
This air conditioner will make a beep when the buttons on the control are pushed or if the unit receives a command from the mobile app or remote control. To silence these beeps, simultaneously press the FAN and “-” buttons for 3 seconds.
Press these buttons again to toggle the sound back on.
This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling.
Use the Temperature Increase + / Decrease - pads to set the desired temperature between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature. For Quieter and Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.
ECO Mode
This mode optimizes the cooling power of your air conditioner, thereby saving you energy. Once the set point temperature has been reached, the fan will cycle off to save energy. The fan will cycle back on periodically to insure all cooling capacity in the system is used. This mode is the default mode for the unit. Each time the unit is powered off, it will restart in ECO mode ON. The first time the unit is turned on, the settings will be 70° and Low fan. You can adjust the fan speed and temperature to your personal comfort.
ECO ON—Helps minimize electricity use. It is normal for the fan to cycle off and then back on in this mode. This on/off cycle can repeat multiple times. Because the fan will cycle off, you may notice a variation in room temperature and humidity.
ECO OFF—When this mode is not engaged, the fan will run continuously, and in Cool mode the compressor will cycle on and off to maintain room temperature.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
Auto Fan Speed
Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.
NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will automatically restart in the settings last used after the power is restored.
Air Direction
Use the lever to adjust the air direction left and right only.
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Pull the tab on the right side of the unit until the filter is out.
To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
How to Insert the Batteries in the Remote Control
NOTES:
(Appearance may vary)
1. WINDOW REQUIREMENTS
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
3. ATTACH THE TOP MOUNTING RAIL SEAL STRIP
(Some models may have the seal strip already attached to the top mounting rail. If applicable, skip this step.)
Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail, along the front edge.
4. PREPARE THE AIR CONDITIONER
NOTE: There is a right and a left accordion panel. Be sure to use the proper panel for each side.
5. PREPARE THE WINDOW
Cut the window seal (2 long strips) to the proper length. Peel off the backing and attach the seal to the underside of the window sash. One attached to sash and one attached to sill.
6. INSTALL THE AIR CONDITIONER IN THE WINDOW
NOTE: To prevent the window sill from splitting, drive the pilot holes before driving the screws.
7. INSTALL SUPPORT BRACKET AND FOAM TOP WINDOW GASKET
NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
8. INSTALL FOAM INSULATION
Additional insulation is provided with your window air conditioner to reduce heat leakage into the home, reducing overall energy usage.
NOTE: Be sure to measure each accordion because the length could be different on each side.
NOTE: Be careful to cover the entire accordion.
Air conditioner does not start
Air conditioner does not cool as it should
Air conditioner freezing up
The remote control is not working
Water drips outside
Water drips indoors
Water collects in base pan
Reference file: GE AEC08LXL1 ENERGY STAR® 115 Volt Electronic Room Air Conditioner
Additionally, the document applies to other GE - General Electric models: AEC08, AEC10, AEC12, AEC14, AHC14, AEK08, AEK10, AEK12, AEF08