20
2. Connect neutral wire (white or center wire) (D) of power supply
cord under center terminal block screw (A). Tighten screw.
3. Connect remaining wires under outer terminal block screws
(F). Tighten screws. Finally, reinstall terminal block to dryer rear
panel. Secure cover with hold-down screw.
Standard Power Cord Connectors
Flanged Spade Connector Ring Connector
Connecting Neutral Wire
1. Loosen or remove center terminal block screw (A).
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare
ground wire at 5" (127 mm). Cut 1
1
2
" (38 mm) from 3 remaining
wires. Strip insulation back 1" (25 mm). Shape ends of wires into
a hook shape.
Connecting 3-Wire Connection: Power Supply Cord
Connecting 4-Wire Connection: Direct Wire
ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY)
Connecting Neutral Ground and Neutral Wires
1. Remove center terminal block screw (A) and the neutral
ground wire (B) by removing the green external ground
conductor screw (C).
A
A
D
A
C
B
F