En-3
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing may have an effect on the proper
function or performance of the product.
2 MANUAL AUTO button
Use when the remote controller is lost or there is a malfunction.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
less than 10 seconds.
AUTO
Press more than 10 seconds.
(Only for servicing.*)
Forced cooling
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop forced cooling, press this button or START/STOP button on
the remote controller.
3 Front panel
See page 8
4 Human Sensor
Used for Energy Saving Program. Controls temperature setting by
detecting people in the room.
5 Vertical air ow direction louver
Each time you press Vertical SET button on the remote controller, the
angle of the vertical air ow direction louver moves as follows:
1
2
3
4
5
6
7
8
COOL or DRY mode HEAT mode
12
3
765
*
4
8
*
*: Default setting in each mode.
Do not adjust by hand.
At the beginning of AUTO or HEAT mode, they may stay on position
1 for a while for adjustment.
If the angle is set to position 5-8 for more than 30 minutes in COOL
or DRY mode, the louver will automatically return to position 4.
Keeping the position 5-8 during COOL or DRY mode may cause
condensation to form, and the drops may damage your property.
6 Power diffuser
In conjunction with movement of the vertical air ow direction louver,
the angle of the power diffuser moves as follows:
Vertical air ow
direction louver
Power diffuser
3
76
5
4
2
1
8
In SWING operation, power diffuser does not move.
7 Horizontal air ow direction louver
Each time you press the Horizontal SET button on the remote controller,
the air ow direction range of the horizontal air ow direction louver will
change as follows:
1
2
3
4
5
Horizontal air ow direction louver
54
1
3
*
2
*: Default setting.
8 Drain hose
9 Remote controller signal receiver
CAUTION
For appropriate signal transmission between remote controller and
indoor unit, keep the signal receiver away from the following items
:
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as in-
verter type ones, the signal may not be transmitted properly. In
such a case, consult the store of purchase.
1
14
13
11
12
8
3
4
2
7
5
6
10
9
10
ECONOMY indicator (green)
Lights in ECONOMY operation and in 10 °C HEAT operation.
11
TIMER indicator (orange)
Lights in TIMER operation, and blinks slowly when the timer setting
error is detected.
For details, refer to “Auto-restart function” on page 9.
12 OPERATION indicator (green)
Lights in normal operation, and blinks slowly in Automatic defrosting
operation.
Blinks during Demand Response operation. For details, refer to page
8.
See page 10
13
Air lter
See page 11
14
Air cleaning lters
Purify or deodorize the air, and provide fresh air ow.