It is dangerous to alter the specications or attempt to modify this product in any way.
Technical Information
Technical Information
DIMENSIONS HEIGHT: 150mm
WIDTH: 598mm
DEPTH: 498mm
WEIGHT GROSS: 8,5 kg
NET: 7,5 kg
ELECTRICAL SUPPLY: Voltage (50Hz) 220-240 V
POWER CONSUMPTION: 138W - 150W
FAN MOTOR: 110Wz
LAMP: 28W - 40W
SUITABLE FOR INSTALLATION
ABOVE: ELECTRIC HOB: 7KW (max)
GAS HOB: 10KW (max)
SLOT-IN GAS COOKER 13.5KW (max)
SLOT-IN ELECTRIC COOKER 12.4KW (max)
Note: CE Marking certies that this appliance complies with the requirements laid
down in EEC directive 89:336. (Electromagnetic compatibility) and subsequent
modications and Low Voltage directive 72/23/E.
ELECTRICAL CONNECTIONS
Electrical Requirements
Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your own
safety this should be undertaken by a qualied
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).
Electrical Connection
Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker
hood.
This appliance is tted with a 2 core mains cable
and must be permanently connected to the elec-
tricity supply via a double-pole switch having 3mm
minimum contact gap on each pole. A Switched
Fuse Connection Unit to BS.1363 Part 4, tted
with a 3 Amp fuse, is a recommended mains sup-
ply connection accessory to ensure compliance
with the Safety Requirements applicable to xed
wiring instructions.
This appliance conforms to BS 800: 1988 and
EEC Directive No. 78 308 regarding
suppression of radio and television
interference.
DOUBLE INSULATED DO NOT EARTH