FRAMING BEHIND DRYWALL
wood wall with minimum
thickness of 8 mm
A
B
Ø8
Ø8
A
B
Ø10
Ø10
BB
D
C
Ø10
Ø10
9
INSTALLING MOUNTING BRACKETS
1. Construct wood wall framing with
minimum thickness of 8 mm (0.3") that
is flush with interior surface of wall
studs.
Make sure:
a. the framing is centered over
installation location;
b. the height of the framing will allow
the mounting brackets to be
secured to the framing.
2. After wall surface is finished, secure
mounting brackets to framing using the
assembly scheme.
Fix the connector box to the motor junction plate
with two 3,5 x 9,5 RYSB screws as shown.
To prepare the hanging plate for
installation:
Pull each tab upward, then retighten
each screw.
WARNING!
Be sure the bulb is cool before trying to change it.
1
2
REPLACEMENT OF LIGHTING COMPONENTS
Disconnect the hood.
Remove the aluminum cassette filter.
In order to change the 50-watt halogen light bulb, refer to diagram below. (1) Press
down on the back part of the lamp holder and (2) turn it counter-clockwise.
Replace old bulb with new one. Turn in reverse direction when installing new bulb.
50-W Halogen bulb
Note: Replacement bulbs can be purchased directly from SUMMIT by calling us at
1-800-932-4267 or by going to our website at www.summitappliance.com/support.
Have the model number of your range hood handy.
MOVING THE HOOD
If you expect to have to move your range hood:
* Keep original packaging. Move your hood using original packaging; comply
with moving instructions printed on the packaging.
If you do not have original packaging:
* Do not put any load on the range hood.
* Avoid any possible impacts.
* Pack the hood in such a way as to prevent damage.
14