tf cooktopisusedinanewbranchdrcuit
installation(1996NEC),mobilehome,recreational
vehicle,orwherelocalcodes DO NOT permit
grounding through the neutral (white) wire:
tf your cooktop has a 3-wire cable (see figure 6):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. Cap the white wire from the power supply cable if a
3-wire appliance cable is supplied.
4. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 6.
Cable from Power Supply
_-_ 1 -White Wire
GroundWire
Red p_)
___" _don Box
Ground ' / _'_ U.L.-Listed Conduit
(Bare or Green Wire) _ Connector (or CSA
listed)
Cable from appliance
Figure 6
4-WIRE GROUNDED JUNCTION BOX
tf your cooktop has a 4 wire cable (see figure 7):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 7.
Cable from Power Supply
Ground Wire
Red
Ground Wire
(Bare
Wire)
Wires
Black
Conduit
Junction Box Connector (or CSA listed)
Cable from appliance
Figure 7
Models 36" with Warmer Zone
4-WIRE GROUNDED JUNCTION BOX
If connecting to a 4°wire power supply
cable electrical system, the appliance frame
connected ground wire MUST NOT be connected to
the neutral wire of the 4-wire electrical system.