Loading ...
Loading ...
Loading ...
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
(for adjusting dryer feet)
Level
Vent clamps
Caulking gun and compound
(for installing new exhaust
vent)
Tin snips (new vent
installations)
¼" nut driver
(recommended)
Tape me asure
Pliers
For All Installations:
Gas Installations:
8" or 10" pipe wrench
8" or 10" adjustable wrench
(for gas connections)
Pipe-joint compound
resistant to LP gas
Parts supplied
Non-Steam Models
4 Leveling legs
Steam Models
A
B
C
D
E
A. Leveling legs (4)
B. “Y” connector
C. Short inlet hose
D. Inlet hose with right-angle
connector
E. Rubber washer
Remove parts package from dryer drum. Check that all parts
are included.
NOTE: Do n
ot use leveling legs supplied with dryer if installing
on a pedestal.
Parts needed
Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements” before
purchasing parts.
Mobile home installations require
metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the “Assistance
or Service” section in your Use and Care Guide.
Optional Equipment
Refer to your Use and Care guide for information about the
accessories available for your dryer.
Location Requirements
You will need
A location that allows for proper exhaust installation.
See “Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the dryer.
See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs
(90.7 kg). The combined weight of a companion appliance
should also be consider
ed.
A level floor with a maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer
Feet Kit, Part Number 279810. Clothes may not tumble properly
and automatic sensor cycles may not operate correctly if dryer is
not level.
For a garage installation, you will need to place the dryer at least
18" (460 mm) above the floor. If using a pedestal, you will need
18" (460 mm) to the bottom of the dryer.
Steam models only: Cold water faucets located within
4 ft (1.2 m) of the dryer, and water pr
essure of 20-100 psi
(137.9-689.6 kPa). You may use the cold water supply from
your washer using the “Y” connector provided.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatur
es, the dryer might not shut off at the end of an
automatic sensor cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be
exposed to
water and/or weather.
Check code requirements. Some codes limit, or do not permit,
in
stallation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Loading ...
Loading ...
Loading ...