9
!0 CONNECTING THE COOKTOP TO THE MAINS POWER SUPPLY
!1 FIT CLAMPING BRACKETS BASED ON THE
BENCHTOP THICKNESS
!2 SECURE TO BENCHTOP
IMPORTANT!
This cooktop must be connected to the mains power supply only by a suitably qualified
person.
To connect the cooktop to the mains power supply, do not use adapters, reducers, or
branching devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
temperature will not exceed 75
o
C at any point.
Before connecting the cooktop to the mains power supply check that:
The domestic wiring system is suitable for the power drawn by the cooktop.
The voltage corresponds to the value given in the rating plate
The power supply cable sections can withstand the load specified on the rating plate.
Power supply
CI302DTB3 3700W@ 220-240V 1N ~ 16A*
CI603DTB2 6950W@ 220-240/380-415V 2N ~ 30A
CI604DTB3 7000W @ 220-240/380-415V 2N ~ 30A
CI754DTB2 7400W @ 220-240/380-415V 2N ~ 32A
CI905DTB2 9800W @ 220-240/380-415V 3N ~ 43A
CI905DTB3 11100W @ 220-240/380-415V 3N ~ 48A
*The CI302DTB2 comes supplied with a cable. This must be wired into a suitably rated plug,
permanent connection outlet or power isolator.
IMPORTANT!
Check with an electrician whether the domestic wiring system is suitable without alterations.
Any alterations must only be made by a qualified electrician.
Connection diagrams
12-40mm
40mm+
view from below
Repeat on all the other brackets
PE
1
2
3
4
5
N
L
PE
1
2
3
4
5
N
L
1
L
2
PE
1
2
3
4
5
N
L
1
L
3
L
2
PE
1
2
3
4
5
N
L
Single-phase connection
220-240V~
Single-phase connection
220-240V~
Two-phase connection
380-415V 2N~
Three-phase connection
380-415V 3N~
CI905DTB2, CI905DTB3
CI302DTB3, CI603DTB2, CI604DTB3, CI754DTB2
No. of brackets and slot positions depends on model
Fit a minimum of
2 brackets on opposing sides
Secure on at least 2
opposing sides