Loading ...
Loading ...
Loading ...
INSTALLATION MANUAL---Information for the installer
(1) Refer to the data rating label sticked on the outdoor unit.
TIGHTENING TORQUE FOR PROTECTION CAPS AND FLANGE CONNECTION
22
PIPE
1/4
(6)
3/8
( 9.52)
1/2
( 12)
5/8
( 15.88)
TIGHTENING TORQUE
[N x m]
TIGHTENING TORQUE
[N x m]
CORRESPONDING STRESS
(using a 20 cm wrench)
15 - 20
31 - 35
35 - 45
75 - 80
Service port nut
Protection caps
7 - 9
25 - 30
wrist strength
arm strength
arm strength
arm strength
MODEL capacity (Btu/h)
7k
9k
12k
15/18k
22/24k
28/30k/36k
Liquid pipe diameter
Gas pipe diameter
Lenght of pipe with standard charge
Type of refrigerant(1)
1/4
(6)
1/4
(6)
1/4
(6)
1/4
(6)
3/8
( 9.52)
3/8
( 9.52)
1/2
( 12)
3/8
( 9.52)
3/8
( 9.52)
5/8
( 15.88)
5/8
( 15.88)
3m 3m
3m 4m
4m 4m
R410A R410A R410A R410A R410A R410A
MODEL capacity (Btu/h)
9k
12k
15/18k
22/24k
Liquid pipe diameter
Gas pipe diameter
Lenght of pipe with standard charge
Type of refrigerant(1)
1/4
(6)
1/4
(6)
1/4
(6)
3/8
( 9.52)
3/8
( 9.52)
1/2
( 12)
3/8
( 9.52)
5/8
( 15.88)
3m
3m 4m
4m
INVERTER TYPE
3/8
( 9.52)
FIXED-SPEED TYPE
R410A R410A R410A R410A R410A
3m
1/2
( 12)
Loading ...
Loading ...
Loading ...